2.2.11. Sensor Terminal Block
Connect sensors (dry contact type) with each ground (GND) line to “G” pin.
2.2.12. Alarm Terminal Block
Connect various alarm devices controlled by relay output.
Note
Support both N/O (Normal Open) and N/C (Normal Close) types of sensor. If connected sensor is not
functioning, ensure wiring is correct. The connection method may differ according to the type of P/T/Z controller.
Enquire to your vendor for guidance.
Note
No.
Sensor
No.
Alarm
No.
PTZ
2 Sensor 1
5 Alarm 1 (+)
1 RS 485 D+
3 Sensor 2
10 Alarm 1 (-)
6 RS 485 D-
7 Sensor 3
8 Sensor 4
4 Sensor Ground
9 Sensor Ground
2.2.13. Power Input
Before connecting the power cord to the system, check if the power is in accordance with the system specification.
2.2.14. Grounding Terminal
It is recommended for user to make grounding to protect the system against external electrical surge.
2.3 IR Remote Controller
In order to use IR Remote Controller, the ID of the IR Remote Controller must be same as the ID of the DVR.
(Default ID # for DVR and IR Remote Controller is “0”.)
If you have more than two DVRs, you are able to control them individually with just one remote controller by setting up
‘REMOTE ID’. (The Remote ID is adjustable from ‘0’ up to ‘255’.)
Procedure 1
‘REMOTE ID’ Setup in the DVR
To setup the “REMOTE ID” for IR
remote controller, firstly decide the
initial REMOTE ID in the DVR.
MENU SYSTEM SYSTEM INFO
REMOTE ID
The Remote ID is adjustable from ‘0’
up to ‘255’.
For example, change ‘REMOTE ID’ to
‘99’ and click ‘SAVE’ to save the
changed setting as shown on the right.